Coating Still Protects the Base Material Reliably Against Erosion After 12 Years in Service

This project involved on‑site coating of a shell‑and‑tube heat exchanger in a hazardous‑waste incineration plant treating hospital waste. Due to very high flue‑gas temperatures and heavy dust loading, the weld seams in particular were subject to rapid wear.

To address this, the entire tube sheet surface – including all weld seam areas – was coated with an extremely temperature‑ and wear‑resistant Fe‑Cr alloy. As a result, the service life of the component has been extended more than fivefold, without any repairs to the welds being required. Even now, after 12 years in operation, the coating still protects the base material reliably and effectively against erosion.

Where necessary, subsequent coating or repair of already installed heat exchangers is also possible.